The Export Project Parameters as FP.txt command is to export all project parameters of the current project model to an external text file as PP.txt.
If the current open model in Revit is a project, the command will be enabled. When it is clicked, a PP.txt file is asked to be created or picked. Then all project parameters of the current project model will be exported to the text file. Here is an example.
Name Group Type Shared (GU)ID Instance CanVary Value Categories Description
Start Reaction - Live Analysis Results Force True b29fdb54-5feb-4f0d-bbbd-9dafeea7f20c True False Structural Framing
REBAR Other Text False 40080556 True True Structural Framing
Top Bars Other Text False 25180685 True True Structural Framing
TypeParameter Dimensions Length False 25299579 False False Mass;Levels;Ramps
End Reaction - Live Analytical Alignment Force True 5846e8af-67f4-4346-1111-bcc62d9ecd85 True True Duct Accessories;Duct Fittings
Force_mtrl Analysis Results Force True 8d568e65-ab2d-48c0-a29f-ec32a039be3d True False Project Information;Structural Framing
NBSDescription Other Text True f3b4c178-53c0-41d2-aa02-5e75ba8d7ceb True True Project Information;Structural Framing
Revision Other Text True d84be8cd-8e1e-4a3d-b98b-97f07c6ababb True False Project Information;Structural Framing
CeilingRAPlenum Electrical Engineering Yes/No True da1ca202-95a1-4ca5-9758-93ffdc1261a4 True False Conduit Runs;Conduits;Conduit Fittings
CenterlineAirVelocity Electrical Engineering Text True 32f284e1-a25f-45f8-b3d7-1c271bbfce5c False False Conduit Runs;Conduits;Conduit Fittings
ChamberLengthOrRadius Electrical Engineering Length True effd11d1-fffc-4565-94f8-8e732fccb535 True False Conduit Runs;Conduits;Conduit Fittings
ChamberWidth Electrical Engineering Length True 39305f2c-9648-4f3e-a486-9a83a7b42b75 True False Conduit Runs;Conduits;Conduit Fittings
ChangeDescription Electrical Engineering Text True 1370d25e-2d64-487d-9035-cc76c5268bb8 False False Conduit Runs;Conduits;Conduit Fittings
CharacteristicTripCurve Electrical Engineering Text True 599e5a6a-eefb-4df6-90d9-303b7df6571a True False Conduit Runs;Conduits;Conduit Fittings
ChargePressure Electrical Engineering Pressure True 75a6a349-7052-4566-9167-1f7cb46e0d10 True True Conduit Runs;Conduits;Conduit Fittings
CircuitBreakerType Electrical Engineering Text True 1d5a9e01-a676-4c78-90ff-1e46b293ee6c False False Conduit Runs;Conduits;Conduit Fittings
CircuitType Electrical Engineering Text True 627ea631-2f14-4b18-b696-ecf8dd2b3f5d True True Conduit Runs;Conduits;Conduit Fittings
CisternCapacity Electrical Engineering Volume True b605399d-9a12-4117-b9b5-a58ad62e6003 True False Conduit Runs;Conduits;Conduit Fittings
If the PO.txt is viewed in the notepad directly, it will be clearer.
As can be seen, all columns are nicely formatted so that people can visually inspect the project parameters easily. The PP.txt can also be a good archive file or print hard copy.
The parameter Name, Group, Type, Shared, (GU)ID, Instance, CanVary, Value, Categories and Description are all straightforward.
All of these can be exercised in the trail edition of Revit Parameter Organizer.